2.1.2 Operation Mode Keys of Injection Molding Machine Running Techmation Controller

In this article, we will show you the pictures and brief function specifications for the operation mode keys of injection molding machines Running Techmation Controller like Guanxin, Powerjet, Haixing, Yizumi, etc. And kind warnings tip in the daily operation. Manual Key: This key has several functions. It can used to change from Auto Mode into Manual mode as well as a reset key for that and alarm settings. Semi-Auto Key: Press this key to run the machine in Semi-auto mode. At the end of each cycle, the operator shall open and then close the safety door to activate the next cycle running. Sensor Auto Key: Press this key to run the machine in Auto Operation mode with the Photo Sensor activated. At the end of each cycle, the

Read more

2.1.1 Control Panel and Keys of Techmation Controller on Guanxin Injection Molding Machines

The Control Panel and Keys of Techmation Controller is covered with a protective Mylar layer to make the panel water, dirt and abrasion resistant. All keys are operated through type A mechanical contact switches to provide for reliability and a long service life.On each key, it is printed with key name and its corresponding draft. At the read side of panel, there is a electronic board which has Type A mechanical contact switches to provide for reliability and a long server life for several million switches. If you have any trouble with the switches, you can use the backup switches instead of the damaged switch. The injection moulding machine control panel keys allow you to switch between different machine operating modes and to manually control the operation of

Read more

1.4 Robot functions and settings of Injection Molding Machines

Robot functions and settings of Guanxin Injection Molding Machines running Techmation controller. This section will introduce the processes and how to set the auto robot on the machine. Press the Manual key to activate the Manual mode . Switch the HMI display to the Others setting screen by pressing F5 ejector then F3 function which is used according to the equipment of the machine.(If there is no robot equipment then this function screen will not exists) Auto Power Door mode: Press drop-down button to enter the selection mode. After charging, the power door will open automatically. But before next cycle, you have to press the button to close the door to activate the next cycle. If this function is disabled, the safety door will not close or open automatically,

Read more

1.3 Production Monitor Setup Instruction of Techmation Controller on Injection Molding Machine

A article about production monitor setup instruction of Techmation Controller on Guanxin injection molding machines. Includes the processes and specifications you may meet in daily operations. Press Manual key to enter into Manual mode . This control allows you to set the down limit and uplimit values for each production parameters. Once the current production parameter value is out of the presetting value, the controller will give an alarm and stop the machine. The controller will record the time of the tupe of error that caused the alarm. To access the Alarm/Error Message display screen, please press F10 .Press again F2  production monitoring to enter the alarm display screen.                       In order to enter the automatic alarm screen,

Read more

2.5.1 Plastic Charging and Suck-back Settings of Plastic Injection Machines

In this section, we will talk about how to get to plastic charging and suck-back settings screen. And how to right setting of Charge setting, Suck back setting, Suck back distance before reserve, Charging once again,Cooling before Reserve and Cooling timing,etc. Charge and Suck-back Settings Path: screen –> F4 charge –> F2 charge Charge and Suck-back Settings of Plastic Injection Machines Charge setting: Charging process, a total of 3 stages of pressure, speed control, are free to set its start, the necessary pressure and the speed and location at the last and middle paragraph. Suck back setting: Suck back setting of pressure speed is devided into position or time. If position is selected you only need to insert the suck back distance, if you are not using the

Read more

1.2.4 Heater Setting of Injection Molding Machines

This article is a step by step instruction of how to set the heater parameters of injection molding machines running Tecmachine PLC controller. Include the details of heater setting process & specifications for your study. Press the Manual key to activate the Manual mode . Switch the HMI display to the Temperature setting screen by pressing F8(Temperature). There are maximum 6 zones barrel heating zones to be controlled as the plastic injection machine’s specifications. The temperature can be controlled separately for each zone of barrel heating. The current and preset temperature for each barrel heating zone will be displayed in the right side of screen. Heater Temperature Setting Screen of Injection Molding Machines First, set the Temperature Mode(Half Warm): Choose “Not neccessary” if you want to keep the

Read more

1.2.3 Charging (plasticizing) and suck-back Setting of Injection Machine

Press the Manual key to activate the Manual mode . Switch the HMI display to the Charge setting screen by pressing F4(Charge) on the controller panel of your plastic molding machine. Charge (Plasticizing) is divided into 3 stages. You can set the speed and pressure separately. If it is necessary, you can also execute the suck-back after the charge. Press the manual key and ensure it is under the manual mode. Please press the F2(Charge) on the panel to enter the charging screen .Next, insert the position to transfer the 3 stages charging movement. Charging (plasticizing) and suck-back Setting screen If there is a control back pressure with the setting value of pressure function, you can set the back pressure in order to raise the density of the plastic

Read more

1.2.2 Injection and Hold Pressure Setting of Injection Molding Machines

The controller can be divided into 1-4 stages of injection and 1-3 stages of hold pressure. You can press F3 button to enter into the injection setting screen of your plastic molding machine. Injection Pressure Setting Screen of Injection Molding Machines Press Manual key to enter into Manual mode. First, choose the Hold Pressure Transition mode . Use the drop-down key to choose the Hold Pressure Transition including position/time/pressure. If the Time mode is used, the controller will switch into Hold Pressure after the set injection time had been reached. If the Position mode is used, the controller will switch into Hold Pressure after the preset end injection position had been reached. However, the set time is used as s backup to activate the Hold Pressure stage if

Read more

1.2.1 Nozzle Unit Setting of Injection Molding Machine

Nozzle Unit Setting depends on your requirements you can set up the nozzle/injection unit to retract after injection has finished. The controller offers you 3 different modes to choose from if nozzle/injection unit retraction is needed. Nozzle Settings Process of Plastic Injection Molding Machine Press manual key   on the controller panel of plastic injection molder,to activate the Manual operation mode. Switch the HMI display to the Nozzle setting screen by pressing F7(Nozzle). Nozzle Setting Screen of Injection Molding Machine First step please click to set the nozzle retraction mode, After Charge mode: retract the nozzle /Injection unit after charge (plasticizing) is finished. Before Mold Opening mode: retract the nozzle /Injection unit before mold opening start. After Injection mode: retract the nozzle /injection unit after injection has finished.

Read more

1.1.6 Cores Setting of Injection Molding Machine

Cores Setting Instruction of Injection Molding Machines running Techmation PLC controller Press the Manual key to activate the Manual mode . Switch the HMI display to the Core setting screen by pressing F6  (Cores). Injection Molding Machine Core Setting Process Injection Molding Machine Core Setting Screen Depending on your setup your plastic injection machine may be equipped with up to 3 cores (A, B and C). Each core is controlled separately. Warning: When setting up the core(s), you need pay close attention to make sure the settings will not cause damage to the core(s) and/or the plastic injection mold. Since the cores are freely programmable it is impossible for the controller to prevent all possible settings errors. First, choose up arrow or down arrow to select the ABC

Read more

1.1.5 Air Blast Setting of Injection Molding Machine

The plastic injection machine provides an air blast ejection option for the moving platen(the moving platen) as well as for the stationary platen(the fixed platen) Press the Manual key to activate the Manual mode. Switch the HMI display to the Ejection setting screen by pressing F5 (Ejector) . Set the duration of air blast for each platen Set the plastic mold opening position at which you want to activate the air blast. If required, please set the Delay Time to activate the air blast. After setting all parameters for air blast, please try to test all the presetting under Manual mode to check for optimum machine performance, if you encounter any problems during the operation, please press Manual key  to stop the machine from operating.

Read more

1.1.4 Ejector Settings in Injection Molding Machines

The ejector settings can be operated in three different modes to knock the finished product out of the mold at the end of mold opening. You can choose between the Hold, Count Number and the Vibration modes. Warning: Hold mode can be used only in semi-automatic operation. Hold Mode:The ejector moves forward according to the ejector settings and the product is dropped or taken out. After the safety gate has been opened and closed the next cycle will start.   Count Number mode: The ejector is activated according to the Ejector and Ejection Cound settings. This mode is usually used for automatic machine operation. It does not require the opening and closing of the safety door to continue the production cycle.   Vibration mode:The ejector movement is controlled by

Read more

1.1.3 Mold Opening Operation on Injection Molding Machine

Mold closing is executed in four phases: Mold Opening Stage 1, Mold Openning Stage 2, Mold Open Stage 3, and Mold Open Stage 4. Press the Manual key to activate the Manual mode. Switch the HMI display to the Clamp Setting screen by pressing F2 (Clamp) . Then, enter the desired hydraulic speed and pressure setting for the 4 mold opening stages. You have to ensure that those settings allow for a smooth, jerk-free movement of the plastic injection mold. Set the hydraulic speed for the Mold Opening Stage 1 in order to separate the mold platen smoothly. Adjust the transition point for switching from Mold Openning Stage 1 to Mold Opening Stage 2 according to your requirement. The transition point setting of switching from Mold Open Stage 3

Read more

1.1.2 Mold closing and mold protection – Injection Molding Machine Manual

There are 5 stages of pressure & speed controlled for mold closing: Mold Close Stage 1, Mold Close Stage 2, Low Pressure Mold Protection and High Pressure.For optimum productivity mold closing should be excecuted as fast as possible. However, it is important to preset correct data to ensure the protection of the plastic injection molds. For this reason pay particular attention to the Low Pressure Close mold part. Press the Manual key to activate the Manual mode . Switch the HMI display to the Clamp Setting screen by pressing F2  mold platen key. Check and set the Max. Mold opening stroke and ensure that it will not exceed this stroke. Next, enter the desired speed and pressure for the 4 stages of mold closing. You have to ensure

Read more

1.1.1 Mold height adjustment – Injection Molding Machine Manual

When changing the mold follows the injection molding machine manufacturer’s instruction at all times to avoid the possibility of serious injuries to the machine operators. After you fix the mold on injection molding machine, please ensure that all the parameters for the mold and the injection unit had been properly aligned to avoid damage to the machine. In addition, you must make sure that the barrel/mold platen units are properly connected, and mold had been mounted securely. 1.1.1    Mold height adjustment During the installation of the plastic injection mold, please use the Mold Adjustment keys   to adjust for mold thickness.Press the Reduced Mold Height Adjustment key  to roughly reduce the mold height (reduce distance between moving and static platen), or press the Increased Mold Height Adjustment key

Read more